Inverter MUST 2kW, 1-phase, DC12V, PURE SINE WAVE

  • Ražotājs:
  • Modelis:
    NV820672
  • Pieejamība:
    1 pcs.
415,03€
Noliktavā (1)
MUST EP3000 PLUS 2kW, 1-phase, 12V, pure sine wave inverter with integrated AC charger, from 35A to 70A. Features: EP3000 PLUS Low Frequency Power Inverter/Charger is economical pure sine wave inverter, with AC charger from 20A to 60A; Solar/AC priority is configurable, when setting solar priority, solar will charge batteries as first priority, and AC can also charge batteries when solar charger current is too lower . With pure copper transformer, it enables inverter to operate with all kinds of home appliances.
 Specifications

Nominal battery system voltage12V DC
Inverter Output
Rated power2000W
Surge power6000VA
Capable of starting electric motor1HP
Waveformpure sine wave
Nominal output voltage RMS220V / 230V / 240V AC ±10%
Output frequency50Hz/60Hz ±0.3Hz
Inverter efficiency (Peak)>88%
Line mode efficiency>95%
Power factor1.0
Typical transfer time10ms (max)
Input AC
Voltage230V AC
Selectable voltage range96~132V AC 155~280V AC (for personal computers)
Frequency range50Hz/60Hz (Auto sensing) 40~80Hz
Battery
Minimum start voltage(10V/10.5V/11V) +0.5V
Low battery alarm(10V/10.5V/11V) +0.5V
Low battery cut off10V/10.5V/11V
High voltage alarm(13.8-14.5V) +1V
High battery voltage recover(13.8-14.5V) +0.5V
Idle consumption - Search modeLoad ?100±20W (220V)
Charger
Output voltageDepends on battery type
Charge AC input breaker rating2-3K/30A
Overcharge protection15.7V DC
Maximum charge current60A
Bypass protection
Input voltage waveformSine wave (grid or generator)
Nominal input frequency50Hz or 60Hz
Overload protectionCircuit breaker
Output short circuit protectionCircuit breaker
Bypass breaker rating1-3K/30A
Max bypass current30A
Other specifications
Dimensions(W*H*D)423*247*197 mm
Package dimensions(W*H*D)585*387*322 mm
Net weight21.1 kg
Gross weight24.1 kg
Operating temperature0°C to 40 °C
Storage temperature-15°C to 60 °C
Audible noise60dB max
DisplayLED+LCD
  Warranty:  The warranty of the voltage converter (inverter) is valid from the day when we (the seller) is provided with the serial number of the inverter, the purchase invoice, a certified electrician's certificate about the installed: 1) Lightning protection and overvoltage limiter (on the input side) 2) Lightning protection (between solar panels and inverter) 3) DC voltage switch between panels and inverter 4) Dedicate grounding for solar panels separated from grounding of the house
 The 2-year (24-month) manufacturer's warranty begins from the day of purchase, but comes into effect only after submission of these documents. Note: Lightning strike is not a valid warranty claim, it is classified as insurance claim.